Concrete Mix Design with Portland Pozzolana Cements
Concrete is a widely used structural material consisting essentially of a binder and a mineral filler. It has the unique distinction of being the only construction material actually manufactured on the site, or in a RMC plant whereas other materials are merely shaped to use at the worksite.
Concrete has become an indispensable construction material. In the present scenario concrete has crossed the stage of four component system i.e. cement, water, coarse aggregate and fine aggregate. It can be combination of more number of ingredients such as fly ash, ground granulated blast furnace slag, silica fume, rice husk ash and admixtures etc. are generally used in concrete production in practice which depends upon the requirement and the availability of the expertise.
The fundamental requirement of a concrete mix is that it should be satisfactory both in the fresh as well as in the hardened state, possessing certain minimum desirable properties like workability, strength and durability. Besides these requirements it is essential that the concrete mix is prepared as economically as possible by using the least possible amount of cement content per unit volume of concrete, with due regard to the strength and durability requirements. Since concrete is produced by mixing several discrete material, the number of variables governing the choice of mix design are necessarily large. However continuous research work in this field by various investigators, has helped to identify the major parameters controlling the proportions of ingredients in the mix.
The basic principle which is generally used for mix design for proportioning mixes is Abram's law for strength development. According to this law, for any given conditions of test the strength of workable concrete mix is dependant only on the water-cement ratio. Lesser the water-cement ratio in a workable mix greater will be its strength. From practical considerations compressive strength is taken as an index of acceptability. Mix proportioning is normally carried out for a specific characteristic compressive strength requirements ensuring that the mix so proportioned should satisfy the workability requirements without segregation and bleeding of concrete.
The following data are required for mix design:
Table 3: Environmental Exposure Conditions (Clauses 8.2.1 and 35.3.2 | ||
SI. No. | Environment | Exposure Conditions |
i) | Mild | Concrete surfaces protected against weather or aggressive conditions, except those situated in coastal area. |
ii) | Moderate | Concrete surfaces sheltered from severe rain or freezing whilst wet Concrete exposed to condensation and rain Concrete continuously under water Concrete in contact or buried under non-aggressive soil/ground water Concrete surfaces sheltered from saturated salt air in coastal area |
iii) | Severe | Concrete surfaces, exposed to severe rain, alternate wetting and drying or occasional freezing whilst wet or severe condensation. |
iv) | Very severe | Concrete surfaces exposed to sea water spray, corrosive fumes or severe freezing conditions whilst wet Concrete in contact with or buried under aggressive sub-soil/ground water |
v) | Extreme | Surface of members in tidal zone Members in direct contact with liquid/solid aggressive chemicals |
This ratio should be selected based upon the relationship between target mean compressive strength of concrete and Compressive strength of cement. IS: 10262-1982 fig. 2 gives the values of water-cement ratio for various cements. The water-cement ratio can also be taken from table (5) of IS:456-2000 for particular environmental exposure conditions as starting point. The supplementary cementitious material that is mineral admixtures shall also be considered in water-cement ratio calculations.
The above selected water-cement ratio should be checked against limiting water–cement ratio for the requirement s of durability and the lower of the two will be adopted.
Table 5: Minimum Cement Content, Maximum Water-Cement Ratio and Minimum Grade of Concrete for Different Exposures with Normal Weight Aggregates of 20 mm Nominal Maximum Size | |||||||
SI. No. | Exposure | Plain Concrete | Reinforced Concrete | ||||
Minimum Cement Content kg/m3 | Maximum Free Water-cement Ratio | Minimum Grade of Conrete | Minimum Cement Content kg/m3 | Maximum Free Water-cement Ratio | Minimum Grade of Conrete | ||
(1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) |
i) | Mild | 220 | 0.60 | - | 300 | 0.55 | M 20 |
ii) | Moderate | 240 | 0.60 | M 15 | 300 | 0.50 | M 25 |
iii) | Severe | 250 | 0.50 | M 20 | 320 | 0.45 | M 30 |
iv) | Very severe | 260 | 0.45 | M 20 | 340 | 0.45 | M 35 |
v) | Extreme | 280 | 0.40 | M 25 | 360 | 0.40 | M 40 |
Notes |
Table: Maximum water content per cubic meter of concrete | ||
S.No. | Nominal maximum size of agg. | Maximum water content |
1. | 10 mm | 208 kg |
2. | 20 mm | 186 kg |
3. | 40 mm | 165 kg |
The above table is for angular coarse aggregates and for 25 to 50mm slump range. |
This may be calculated from the free water-cement ratio and the quantity of water per unit volume of concrete. The cementitious material content so calculated shall be checked for minimum content for the durability requirements and the greater of the two values adopted. The maximum cement content shall be as per IS: 456-2000.
Table: Volume of coarse aggregate per unit volume of total Aggregate for different Zones of Fine Aggregate | |||||
S, No. | Nominal Maximum Size of Aggregate | Volume of Coarse Aggregate* per unit Volume of Total Aggregate for Different Zones of Fine Aggregate | |||
| mm | Zone IV | Zone III | Zone II | Zone I |
1 | 2 | 3 | 4 | 5 | 6 |
i) | 10 | 0.50 | 0.48 | 0.46 | 0.44 |
ii) | 20 | 0.66 | 0.64 | 0.62 | 0.6 |
iii) | 40 | 0.75 | 0.73 | 0.71 | 0.69 |
*Volumes are based on aggregates in saturated surface dry condition. |
This is obtained by finding out the absolute volume of cementitious material; water and the chemical admixture by dividing their masses to their specific gravity, multiplying by 1/1000 subtract the results of this summation from unit volume.
The above obtained values are distributed into coarse and fine aggregate fractions by volume in accordance with coarse aggregate fractions.
The coarse and fine aggregates contents are then determined by multiplying with their respective specific gravities and multiplying by 1000.
The trial mixes shall be made and cubes be tested, if any discrepancies may be observed during concrete making it should be taken into considerations and more trial mixes be prepared and finally the mix which provides sufficient information, including the relationship between compressive strength, water cement ratio and slump, from which the mix proportions for field trials may be arrived at. The concrete for field trials shall be produced by methods of actual concrete production.
Grade of Designation | M-25 |
Type of Cement | PPC confirming to Is1489 – Part I |
Maximum Nominal Size of Aggregate | 20 mm |
Minimum Cement Content | 300 kg |
Maximum water cement ratio | 0.5 |
Workability | 60 mm slump |
Type of Aggregate | Crushed Angular aggregate |
Maximum Cement Content | 450 kg/m3 |
Chemical Admixtures | Fosroc (as supplied) |
Sieve Analysis of Coarse Aggregate | ||||||
IS sieve No | Analysis of Coarse Aggregate Fraction, % passing | Percentage of Different Fractions | Remarks | |||
| I | II | I | II | Combined |
|
|
|
| 30% | 70% | 100% |
|
20mm | 81 | 100 | 24.3 | 70 | 94.3 | Conforming to Table: 2 of IS383 |
10mm | 0.8 | 47 | .24 | 32.9 | 33.14 | |
4.75mm | 0 | 4.4 | 0 | 3.08 | 3.08 |
|
2.36mm | - | - | - | - | - |
|
IS sieve No | Percentage passing | Remarks |
4.75mm | 100 | Conforming to Zone IV Table 4 of IS383 |
2.36mm | 98.5 | |
1.18mm | 96 | |
600 µm | 85 |
|
300 µm | 3 |
|
150 µm | 0 |
|
Target Mean Strength F
t
= f
ck
+ 1.65 S
= 25 + 1.65 * 4.0
= 31.6 N/mm
2 The mix proportions obtained for above materials are:
Water : Cement : Sand : Aggregate = 184.5 lits: 410 kg: 606 kg : 1176 kg
w/c ratio = 0.45, 1 : 1.478 : 2.868
Admixture dose = 0.25 % of weight of cement in terms of volume of admixture.
Cube strength after 7 days = 24.0 N/mm
2 , 20.88 N/mm
2 , 22.22 N/mm
2 Average Value = 22.36 N/mm
2 Cube strength after 28 days = 31.11 N/mm
2 , 34.66 N/mm
2 , 31.11 N/mm
2 Average Value = 32.29 N/mm
2
Conclusions
The concrete mix produced with blended cements (PPC Cement) possesses nearly same quality as of OPC except with adjustments in water cement ratio as such the heat of hydration of PPC is lower than OPC the cement content obtained is slightly higher for blended cements. Hence, it is concluded that with proper quality control and supervision at site, the effectiveness of concrete produced with blended cements will be increased. It will also satisfy the requirements of workability, strength and durability.