Mollier Diagram for Water-Steam

The diagram below can be used to determine enthalpy versus entropy of water and steam.

The Mollier diagram is useful when analyzing the performance of adiabatic steady-flow processes, such as flow in nozzles, diffusers, turbines and compressors. 

See also Water - Enthalpy (H) and Entropy (S) for figures and tabulated values at varying temperatures

Dryness Fraction

The quantity of saturated vapor in unit mass of wet vapor, denoted by x, is referred to as the

dryness fraction, or quality,

of the vapor. 

Convert to other Units

Example - Enthalpy

The enthalpy in saturated steam (x = 1, the bold red line in the diagram) with pressure 10 bar can be estimated to aprox.

2770 kJ/kg

The value can be verified by using the steam table.