Before
discussing about the induction motor drives we have to understand and know
about induction
motors. In
very simple words induction motors can be described as a three phase, self starting constant
speed AC motors. The reason of describing induction motors as constant speed is
because normally these motors have a constant speed depending on the frequency
of the supply and the no of windings. In the past it was not possible to control
the speed of the induction motors according to the need. That’s why their use
was limited and despite having many a motors they advantages over DC motors
they could not be used because of this disadvantage. But at the field of
drivers have improved due to the availability of thyristors or SCRs, power
transistors, IGBTs and GTOs the variable speed induction motor drives have been
invented. Though the cost of these drivers are more than dc driver, but still
the use of induction motors are increasing and they are replacing DC motors because of their
advantages. While discussing about this topic we will look through the
starting, braking and speed control of
induction motors.
We know that the
induction motor is self
starting i.e when
the supply is given to the motor it starts to rotate without any external help.
When an induction motor is started as there is no resistance initially (i.e,
during starting), there is a tendency of huge current flow through the
rotor circuit which may damage the circuit permanently. To overcome this
problem various methods have been introduced to limit the starting current.
Some of the methods are
1. Star delta starter
2. Auto- transformers starter
3. Reactor starter
4. Saturable reactor starter
5. Part winding starter
6. AC voltage controller starter
7. Rotor resistance starter is
used for starting of wound rotor motor.
The induction motor drives are normally designed to run on delta connection,
but during starting the supply is given from star connection because then the
starter voltage and current reduces by 1/√3 times than the delta
connection. When the motor reaches a steady state speed the connection changes
from star to delta connection.
Another type of starting method of induction motors is the auto transformer starting. Since we
know that the torque is proportional to square of the voltage. By auto
transformers the starting voltage and current are reduced to overcome the
problem of overheating due to very high current flow. During starting the ratio
of the transformer is set in a way that
the starting current does not exceed the safe limit. Once the induction motor
starts running and reaches a steady state value, the auto transformer is
disconnected from the supply. The circuit diagram is given here with
Another method
of starting is softstart using saturable reactor
drivers. In this method high reactance is introduced into the circuit so that
the starting torque is closed to zero. Now the reactance is reduced smoothly
during starting and the starting current increases and the torque also
varies steplessly.
In this method the motor starts without any jerk and the acceleration is
smooth, that’s why its called
soft start also.
Unbalanced starting scheme for soft start is another type of starting method
where the impedance is introduced only in one of the supply phases. During
starting the impedance is kept very high so that the motor operates as a single
phase motor, the speed torque characteristics at that time is similar to curve
A in the graph. When the speed attains a steady state value the impedance is
removed completely, at that time the curve is similar to B, which is the
natural characteristics of the matine. This starting method is also without
any jerk and the operation is very smooth.
Part winding starting method is special for squirrel-cage induction motors. In
this method two or more starter winding are connected in parallel. When the
motor starts, any one of the winding is connected as a result the starter
impendence is increased and starting current is reduced. When the steady speed
is acquired by the motor both the windings are connected.
Specially for
wound rotor motors. Rotor resistance starter is used. In this method
external resistors are used in the rotor
circuit to limit the starting current. Maximum value of resistance is chosen to
limit the current at zero speed within the safe value. As the speed increases,
the sectional resistance is the temperature rise is lower than other methods of
starting high acceleration, frequent starts and stops starting with heavy loads
can be done with this type of starting method.
When it comes to controlling an electric machine by electric drivers braking is a very
important term because it helps to decrease the speed of the motor according to
will and necessity. Braking of induction motors can be classified mainly in
three types
1. Regenerative braking.
2. plugging or reverse voltage
braking
3. Dynamic braking which can be further
classified as
● AC dynamic braking
● Self-excited braking using
capacitors
● DC dynamic braking
● Zero sequence braking
To explain that regeneration braking for induction motor, we can take help of
the equation
Pin = 3 N Is Cosθs
Here θs is the phase angle
between the stator voltage and stator current, the simple words whenever this
phase angle exceeds 90° (i.e θs>90°) regenerative
braking can take place. To explain this more clearly and easily we can say that
whenever the speed of the rotor exceeds synchronous speed, regeneration braking
occurs. That is because whenever the rotor rotates at a speed more than
synchronous speed there is a reverse field occurs which opposes the normal
rotation of the motor and therefore braking takes place. Main disadvantage of
this type of braking is that the speed of the motor has to exceed synchronous
speed which may not be possible every time. To acquire regenerative braking at
a lower speed than synchronous speed, variable frequency source can be used.
Plugging of induction motors is done by interchanging any two of the supply
terminals. When the terminals are reversed the operation of the machine changes
from motoring to plugging. From technical point of view and for better
understanding it can be said that the slip changes from ‘s’ to (2-s),
which indicates that due to reversal of the terminals the torque also changes
its direction and braking occurs.
The first classification of dynamic braking of induction motors is AC dynamic
braking any one of the supply phase is disconnected from the supply and then it
is either kept open or connected with the other phase. The first type is known
as two lead connection and the second one is known as three lead connection. To
understand this braking method clearly we can assume the system to be a single
phase system. Now the motor can be considered to be fed by positive and
negative sequence voltages. That’s why when the rotor resistance is high the
net torque is negative and braking can be acquired.
Sometimes capacitors are kept permanent by connected across the supply
terminals of the motor. This is called self-excited braking using capacitors of induction motors.
This type of braking works mainly by the property of the capacitors to store
energy. Whenever the motor is disconnected from the supply the motor starts to
work as a self-excited induction generator, the power comes from the capacitors
connected across the terminals. The values of the capacitor are so chosen that
they are sufficient to make the motor work as an induction generator after
being disconnected from the supply. When the motor works as an induction generator the produced torque
opposes the normal rotation of the motor and hence braking takes place.
Another type of dynamic braking is dc dynamic braking. In this method the
stator of running induction motor drives is connected to dc supply. The
consequences of connecting a dc supply to the stator is as follow, the DC
current produces a stationary magnetic field, in the rotor keeps rotating and as a result there is a induced
voltage in the rotor winding, therefore the machine works as a generator which
opposes the motion of the motor and braking is acquired
We have
discussed about the starting and braking of induction motors but what about
controlling the speed during the running time. Speed control of induction
motors can be done in six methods which are
1. Pole changing
2. Stator voltage control
3. Supply frequency control
4. Eddy –current coupling
5. Rotor resistance control
6. Slip power recovery
We know that the speed of the induction motor is inversely proportional to
number of poles. So it is possible to increase or decrease the speed of the
induction motor if the number of the poles are decreased or increased
respectively. The motor in which the provision of changing the number of poles
is present, they are called ‘pole changing motor’ or ‘multi –speed motor’.
Another method of controlling the speed of induction motor drives is the stator
voltage control. Stator voltage is directly responsible for the rotating speed
of the rotor. Torque is proportional to voltage squared and the current is
proportional to the voltage. So, if the stator voltage is reduced the speed
reduces and similarly if the stator voltage is increased the speed also
increases.
The speed of an induction motor is proportional to the product of the supply
frequency and air gap flux. But as there is a chance of magnetic saturation while decreasing the
supply frequency, that’s why not only the frequency but the v/f ( i. e the
ratio of supply voltage and frequency ) is controlled and this ratio is tried
to be kept constant. And if the speed is needed to be changed the ratio of v/f
is changed accordingly.
The eddy
current speed
control method is done by placing an eddy current clutch between an induction
motor is running at a fixed speed and the variable speed load. Now what is this
eddy current clutch? It is nothing but an induction motor drives in which both stator
and the rotor are allowed to rotate. The rotor is coupled with the main
induction motor. When eddy currents are produced in the rotor drum, their
interaction with the stator field and a torque is produced which rotates the
main motor. By controlling the DC current through the stator winding the speed
of the motor can be controlled.
Depending on the rotor resistance, the speed of the rotor falls or increases.
The variation of speed torque characteristics with respect to change in rotor
resistance is shown in the figures below. This speed controlling method is
better than many other methods because of low cost.