Heat Exchanger Effectiveness

Calculating heat exchanger effectiveness allows engineers to predict how a given heat exchanger will perform a new job. Essentially, it helps engineers predict the stream outlet temperatures without a trial-and-error solution that would otherwise be necessary. Heat exchanger effectiveness is defined as the ratio of the actual amount of heat transferred to the maximum possible amount of heat that could be transferred with an infinite area.

Two common methods are used to calculate the effectiveness, equations and graphical. The equations are shown below:

Description: ht_effectiveness_eq_1

Eq. (1)

 

Description: ht_effectiveness_eq_2

Eq. (2)

 

where:

Â

U = Overall heat transfer coefficient

A = Heat transfer area

Cmin = Lower of the two fluid's heat capacities

Cmax = Higher of the two fluid's heat capacities

Oten times, another variable is defined called the NTU (number of transfer units):

NTU = UA/Cmin

When NTU is placed into the effectiveness equations and they are plotted, you can construct the plots shown below which are more often used than the equations:

Description: ht_effectiveness_1

Description: ht_effectiveness_2

Figure 1: Heat Exchanger Effectiveness

for Countercurrent Flow

Figure 2: Heat Exchanger Effectiveness

for Cocurrent Flow

Then, by calculating the Cmin/Cmax and the NTU, the effectiveness can be read from these charts. Once the effectiveness has been found, the heat load is calculated by:

Q = Effectiveness x Cmin x (Hot Temperature in - Cold Temperature in)

 

and the outlet temperatures can be calculated by:

Description: ht_effectiveness_eq_3

Eq. (3)

 

Description: ht_effectiveness_eq_4

Eq. (4)